Pro View Home Inspection L.L.C.Website: http://www.reporthost.com/gregghi Email: proviewinspects@aol.com Phone: (518) 705-5500 678 Master St. Johnsonville , NY 12094 Inspector: Gerald Gregg
| Property Inspection Report - Sample |
| Client(s): |
John Doe |
| Property address: |
123 Main St Anywhere USA
|
| Inspection date: |
7/2/2008 | This report published on 7/8/2009 10:37:37 AM EDT
View summary page
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
How to Read this Report This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
 |
Safety |
Poses a risk of injury or death |
 |
Repair/Replace |
Recommend repairing or replacing |
 |
Repair/Maintain |
Recommend repair and/or maintenance |
 |
Evaluate |
Recommend evaluation by a specialist |
 |
Comment |
For your information |
Click here for a glossary of building construction terms. Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
Overview: A quiet residential neighborhood Report number: Sample 1 Inspector's name: Gerald Gregg Jr. Time started: 5:50 Time finished: 7:45 Present during inspection: Owner Occupied: Yes Age of building: 34 years old Type of building: Single family Weather conditions: Partly cloudy Temperature: Warm Ground condition: Dry Foundation type: Slab
1) Numerous wall, floor and/or ceiling surfaces were obscured by furniture and/or stored items, preventing a full evaluation of some areas.
2) Concerning mold in a home / building. While we will report any substance that appears to be mold, the only true way to determine if mold is present is to have a mold company/specialist inspect and test for mold. Pro View Home Inspection does not perform mold testing or mold inspection's. Any mention of mold in this report should be considered a recommendation to bring in a mold specialist to inspect and test for mold. If you have a specific concern regarding mold, consult a mold specialist for advice.
Roof inspection method: From Ground Roof type: Hipped Roof covering: Asphalt or fiberglass composition shingles Estimated age of Roof: Middle of its useful life Defects Observed: None Roof Requires: No Action Roof Penetrations: Chimney, Vent Pipes Gutter material: Aluminum Downspout material: Aluminum Chimney appears to be built: within the interior of house Spark arrester/rain cap: noted Chimney made of: Metal Visible Roof Ventilation: Soffet Vents, Roof Vents
3)  One or more downspout extensions are missing and/or ineffective. Recommend installing extensions such as splashblocks or a drain line where missing, or repairing where necessary so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.
 Photo 9 |
 Photo 10 |
Apparent wall structure: Wood frame Wall Covering Material: Vinyl General Condition of Covering: Good Trim: Wood Trim Condition: Acceptable Exterior Doors: Metal Doors: Operated well Windows: Screens, Vinyl Main Entry Porch: Concrete Slab Steps down: One Roof: No Primary service type: Overhead Overhead wires threatened: No Service size: 100 Amp Aluminum Meter amperage (amps): 200 Drip loop present: yes Service voltage (volts): 120-240 Meter caulking intact and sealed: above, below
4) Soil is in contact with or less than 6" from siding and/or trim. Recommend grading soil so there's at least 6" of space between the siding and trim and the soil below.
 Photo 9 |
|
5) Wood trim shows signs of deterioration, requires repair and repainting.
 Photo 7 |
 Photo 8 |
6) Service wires run through tree branches. Not currently threatened but regular maintenance is advisable to prevent any damage to wires.
 Photo 6 |
|
Exterior of foundation walls: concrete Exterior Foundation Exposure: Less than 6 inches Grading within 6 feet of house: About level Grading beyond 6 feet of house: About level Driveway material: Asphalt Driveway condition: Good Walkway to front entry: asphalt Condition of walkway: Good and poses no tripping hazard Trees & Shrubs too close to house: No Fences: Metal Fences felt: secure Deck Location: Rear of house to pool Deck material: wood Steps down to grade: There are three or more steps to grade Visibility under deck: Four foot and clear visibility Support column under deck: wood Condition of the support columns: Acceptable Condition of the guardrail: Acceptable
7) Various pictures of exterior .
 Photo 2 |
 Photo 3 |
 Photo 4 |
 Photo 5 |
# of Bays: One Visibility limited by: stored items Floor: Concrete Floor Condition: Small cracks Walls: Wood Frame Walls: Drywall covered Automobile Doors #: One Style: Overhead Doors operated: easily Rollers making clicking sound: No Lift Cable: Good Condition Is the overhead door balanced: Yes Springs: Good Condition Safety Cable: Attached Electric Car Door Openers: One Operated: Yes, and operated properly Applied resistance and: door did not stop Photo electric device: noted Non-Automobile doors to interior: One Interior Door: Not spring loaded Interior door: Solid Core Windows: None noted Overhead: Closed in ceiling Condition of Roof Underside: Good
8) Garage-house door isn't auto-closing. Recommend installing hinges with springs or an automatic door closing device so door closes automatically to prevent vehicle fumes from entering building.
 Photo 11 |
|
9) The garage vehicle door doesn't appear to "auto-reverse". The door should reverse when closing and when it either strikes something or something passes through a photo sensor at the base of the door. This is a safety hazard, especially for small children. Recommend having a garage door contractor evaluate and repair.
10) Pictures of garage.
 Photo 31
Garage |
 Photo 32 |
Attic access: Pulldown How observed: Limited viewing, looked thru opening only Roof system: rafters Inches apart: 18 inches Roof decking: plywood Attic floor framing: wood Attic floor system: some flooring Attic Ventilation: Soffit Vents, Roof Vents Bathroom vent: appears to go outside Soffit vents: cant determine if working Insulation material: Fiberglass roll or batt Insulation location: floor
11)  Ventilation is substandard in the attic. Inadequate attic ventilation may result in high attic and roof surface temperatures, reduce the life of the roof covering materials and increase cooling costs. High levels of moisture are also likely, and can be a conducive condition for wood destroying insects and organisms. Standard building practices require one square foot of vent area for 150 to 200 square feet of attic space. Vents should be evenly distributed between soffits, ridges and at corners to promote air circulation. A qualified contractor should evaluate and install vents as per standard building practices.
12) Various pictures of the attic.
 Photo 21 |
 Photo 22 |
 Photo 23 |
 Photo 24 |
 Photo 25 |
 Photo 26 |
Main Bathroom: Full Location: Next to kitchen Shower: with tub Tub: Built in Surround: Plastic Surround Condition: Good Number of sinks?: One Sink Type: Vanity Toilet: flushed Toilet Condition: Loose Floor: Ceramic tile Floor Condition: Good Caulking appears: Intact Ventilation: Window, Fan Outlets: One Ground Fault Interupter Outlets?: Yes
13) Toilet appears to be loose and may need reanchoring. Recommend repairing so toilet is securely fastened to the floor.
Sink Type: Vanity Sinks #: One Toilet: flushed Toilet Condition: Good Floor: Ceramic Tile Floor Condition: Good Ventilation: Window Number of outlets: One Ground Fault Interupter outlets: Yes
14) Water stains on ceiling. Possibly from loose toilet directly above this bathroom. Stains were dry to the touch but toilet above should be tightened down to prevent any further damage.
 Photo 17 |
|
Ceilings appear to be made of: Drywall Ceiling Style: Flat Ceiling Condition: Good Major Defects: None Noted Mostly walls appear to be made of:: Drywall Condition: Good Major defects were noted: No Floor coverings are mostly: Wall to wall carpet, Hardwood When bounced on: a normal amount of bounce was noted Generally floors feel: Level Mostly the doors are the following types: Hollow core General door condition: Doors are generally in good condition Windows were mostly observed to be: Double hung Insulated noted in: Most Appear made of: Vinyl Random Tested: Yes Stairs: between living levels Stairs condition: Acceptable
15)  Railing spacing on stairs is too large. The preferred spacing is 4 inches or smaller. This spacing prevents small children from becoming trapped between the spindles. Recommend replacing railing by a qualified person.
 Photo 19 |
 Photo 20 |
16) General interior pictures.
 Photo 28 |
 Photo 29 |
 Photo 30 |
|
Ceilings appear to be made of: Drywall Ceiling Condition: Good Mostly walls appear to be made of.: Drywall Condition: Good Floor Coverings: Wall to Wall When bounced on: a normal amount of bounce Windows are mostly observed to be: Double Hung Insulated glazing noted in:: Most Electrical Outlets: 3 Prong
Cabinets: Wooden Opened and closed and found: seemed to function Cabinets secure: yes Counter Tops: Plastic Laminate Securely fastened: yes Kitchen Floor: Sheet Goods Dishwasher: Kenmore Operated Dishwasher: in use during inspection Dishwasher age: midlife Kitchen Sink: Stainless Steel Ran water and found: No leaks Refrigerator: Kenmore Refrigerator in use during inspection: yes Age: Middle Range:: GE Range type: Free standing, Electric Age: Midlife Operated and found: All burners working Oven: Part of stove Number of Regular outlets in kitchen: Four or more Washing Machine: Maytag Age: midlife Location: In bathroom Observed: Connections for water and drain, Connections for electric Operated: Not operated Dryer: Maytag Dryer age: Midlife Vented to: Exterior Power: Electric Operated: Not operated
17) PIcture of kitchen.
 Photo 27 |
|
Heating System Brand Name: Ruud Apparent age of unit: Midlife Heating system type: Forced hot air System has # of Zones: One Fuel Source: Gas Combustion Air Supply: Interior Automatic shut-off safety devices were noted: above the unit Flue pipes: Noted Flue pipes: pitch up to chimney Distribution system: Ductwork Heat distribution: In most rooms
18) Recommend that this system be serviced every two years in the future by a qualified heating and cooling technician.
 Photo 18 |
|
Estimated age: Older .Made in 1996 Type: Tank Energy source: Natural gas Capacity (in gallons): 30 Brand: Reliance Safety relief valve: was noted Safety extension: was noted Supply shut off valve: Noted Drain discharge to:: Floor Rust or Corrosion: was not noted Tested hot water: Hot water was received at faucets
19) Hot water heater appears to be older than 10 years and is older than its estimated useful life. This hot water heater may need replacing at any time.
Location of Main Panel: Living room Location of main disconnect: No single main disconnect, use all breakers in main panel Primary service overload protection type: Circuit breakers Service conductor material: Aluminum Main disconnect rating (amps): Not applicable, no single main disconnect Branch circuit wiring type: Non-metallic sheathed ("Romex") Solid strand aluminum branch circuit wiring present: No Double tapped breakers: No Room for additional circuit breakers: No Missing Circuit Breaker Covers: No Grounding observed to:: Water main on house side Grounding connection feels: secure If grounded to water main, is meter jumped: yes
20) Panel is filled with no available slots for expansion.
 Photo 12 |
 Photo 13 |
Water service: Public Main entry pipe material: Copper Location of main water meter: Downstairs bathroom Location of main water shutoff: Next to meter Interior supply pipes: Copper Functional Flow: Tested With multiple fixtures running observed: Minimal decrease in flow Waste System Pipes: Plastic House Trap: Noted Main waste line cleanouts: noted Vent pipe observed on roof: Yes
21) PIcture of water meter.
 Photo 14 |
 Photo 15 |
 Photo 16 |
|
The house appears to be built on a slab located at: about grade level. On the exterior perimeter of the slab where visible: cracks were not noted. Interior floor covering is: vinyl, wall to wall carpet
|
|
|
|